BH-0.66、LMK2-0.66I Series of current transformersApplication scopeLow voltage current transformer is···
BH-0.66、LMK2-0.66I Series of current transformers
Application scope
Low voltage current transformer is mainly used for indoor, For the rated voltage of 0.66kV and below, Rated frequency 50 Hz AC circuit, As the current electric energy measurement and relay protection .The product is a new shell type current transformer, The product is a new shell type current transformer, its installation method can use bus or fixed plate fixed installation method, Suitable for any direction installation, A wire for the bus or cable. Product performance in line with the GB - 1208, and passed the CE certification.
Type designation
The normal working conditions and installation conditions
· The installation place:Indoor
· Ambient temperature:-5℃~40℃
· Ambient humidity:Relative humidity is more than 80%
· Altitude:Altitude up to 1000 above sea level
· Atmosphere condition: No serious impurity in the atmosphere
Main technical data
· Rated insulation level:0.72/3kV
· Rated frequency:50 or 60Hz
· Power factor of load: COSΦ0.8 lagging
· Rated secondary current:5A or 1A
Rated ratio(A) | Rated burden(VA) | Through core winding | ||||
1 | 0.5 | 0.5S | 0.2 | 0.2S | ||
75/5 | 2.5 | 1 | ||||
100/5 | 2.5 | 1 | ||||
75/1 | 2.5 | 1 | 1 | |||
100/1 | 2.5 | 1 | 1 |
Type | Size Specification | Overall dimensions | ||
W | H | D | ||
LMK2(BH)-0.66 20I | 20×30 | 49 | 107 | 41 |
Rated ratio | Rated burden (VA) | Through core winding | ||||
1 | 0.5 | 0.5S | 0.2 | 0.2S | ||
20/5 | 5 | 2.5 | 1.5 | 2.5 | 1.5 | 5 |
30/5 | 5 | 2.5 | 1.5 | 2.5 | 1.5 | 5 |
40/5 | 5 | 2.5 | 1.5 | 2.5 | 1.5 | 3 |
50/5 | 5 | 2.5 | 2.5 | 2.5 | 2.5 | 3 |
60/5 | 5 | 2.5 | 2.5 | 2.5 | 2.5 | 2 |
75/5 | 5 | 2.5 | 2.5 | 2.5 | 2.5 | 2 |
100/5 | 5 | 2.5 | 2.5 | 2.5 | 2.5 | 1 |
150/5 | 10 | 10 | 5 | 5 | 5 | 1 |
200/5 | 10 | 10 | 5 | 5 | 5 | 1 |
250/5 | 10 | 10 | 5 | 5 | 5 | 1 |
300/5 | 10 | 10 | 5 | 5 | 5 | 1 |
20/1 | 5 | 2.5 | 5 | |||
30/1 | 5 | 2.5 | 5 | |||
40/1 | 5 | 2.5 | 3 | |||
50/1 | 5 | 2.5 | 3 | |||
60/1 | 5 | 2.5 | 2 | |||
75/1 | 5 | 2.5 | 2 | |||
100/1 | 5 | 2.5 | 2.5 | 1 | ||
150/1 | 5 | 2.5 | 2.5 | 1 | ||
200/1 | 5 | 5 | 2.5 | 1 | ||
250/1 | 5 | 5 | 2.5 | 1 | ||
300/1 | 5 | 5 | 2.5 | 1 |
Type | Size Specification | Overall dimensions | ||
W | H | D | ||
LMK2(BH)-0.66 30IB | 30×30 | 75 | 98 | 42 |
Rated ratio | Rated burden (VA) | Through core winding | ||||
1 | 0.5 | 0.5S | 0.2 | 0.2S | ||
20/5 | 5 | 2.5 | 5 | |||
30/5 | 5 | 2.5 | 5 | |||
40/5 | 5 | 2.5 | 3 | |||
50/5 | 5 | 2.5 | 3 | |||
60/5 | 5 | 2.5 | 2 | |||
75/5 | 5 | 2.5 | 2 | |||
100/5 | 5 | 2.5 | 1 | |||
150/5 | 5 | 2.5 | 1 | |||
200/5 | 5 | 5 | 1 | |||
250/5 | 5 | 5 | 1 | |||
300/5 | 5 | 5 | 1 | |||
400/5 | 5 | 5 | 1 | |||
500/5 | 10 | 10 | 5 | 5 | 5 | 1 |
600/5 | 10 | 10 | 5 | 5 | 5 | 1 |
750/5 | 10 | 10 | 10 | 10 | 5 | 1 |
20/1 | 5 | 2.5 | 5 | |||
30/1 | 5 | 2.5 | 5 | |||
40/1 | 5 | 2.5 | 3 | |||
50/1 | 5 | 2.5 | 3 | |||
60/1 | 5 | 2.5 | 2 | |||
75/1 | 5 | 2.5 | 2 | |||
100/1 | 5 | 2.5 | 1 | |||
150/1 | 5 | 2.5 | 1 | |||
200/1 | 5 | 2.5 | 1 | |||
250/1 | 5 | 2.5 | 1 | |||
300/1 | 5 | 5 | 1 | |||
400/1 | 5 | 5 | 1 | |||
500/1 | 10 | 10 | 5 | 1 | ||
600/1 | 10 | 10 | 5 | 1 | ||
750/1 | 10 | 10 | 10 | 1 |
Type | Size Specification | Overall dimensions | Hole size | |||
W | H | D | d | a | ||
LMK2(BH)-0.66 30I | 30×30 | 60 | 78 | 41 | 32.5 | 32 |
37×30 | 65 | 80 | 37 |
Rated ratio | Rated burden (VA) | Through core winding | ||||
1 | 0.5 | 0.5S | 0.2 | 0.2S | ||
20/5 | 5 | 2.5 | 5 | |||
30/5 | 5 | 2.5 | 5 | |||
40/5 | 5 | 2.5 | 3 | |||
50/5 | 5 | 2.5 | 3 | |||
60/5 | 5 | 2.5 | 2 | |||
75/5 | 5 | 2.5 | 2 | |||
100/5 | 5 | 2.5 | 1 | |||
150/5 | 5 | 2.5 | 1 | |||
200/5 | 5 | 5 | 1 | |||
250/5 | 5 | 5 | 1 | |||
300/5 | 5 | 5 | 1 | |||
400/5 | 5 | 5 | 1 | |||
500/5 | 10 | 10 | 5 | 5 | 5 | 1 |
600/5 | 10 | 10 | 5 | 5 | 5 | 1 |
750/5 | 10 | 10 | 10 | 10 | 5 | 1 |
800/5 | 10 | 10 | 10 | 10 | 5 | 1 |
20/1 | 5 | 2.5 | 5 | |||
30/1 | 5 | 2.5 | 5 | |||
40/1 | 5 | 2.5 | 3 | |||
50/1 | 5 | 2.5 | 3 | |||
60/1 | 5 | 2.5 | 2 | |||
75/1 | 5 | 2.5 | 2 | |||
100/1 | 5 | 2.5 | 1 | |||
150/1 | 5 | 2.5 | 1 | |||
200/1 | 5 | 5 | 1 | |||
250/1 | 5 | 5 | 1 | |||
300/1 | 5 | 5 | 1 | |||
400/1 | 5 | 5 | 1 | |||
500/1 | 10 | 10 | 5 | 1 | ||
600/1 | 10 | 10 | 5 | 1 | ||
750/1 | 10 | 10 | 5 | 1 | ||
800/1 | 10 | 10 | 5 | 1 |
Type | Size Specification | Overall dimensions | Hole size | |||
W | H | D | d | a | ||
LMK2(BH)-0.66 40I | 30×40 | 75 | 97 | 44 | 30.5 | 42 |
Rated ratio | Rated burden (VA) | Through core winding | ||||
1 | 0.5 | 0.5S | 0.2 | 0.2S | ||
150/5 | 5 | 2.5 | 1 | |||
200/5 | 5 | 5 | 1 | |||
250/5 | 5 | 5 | 1 | |||
300/5 | 5 | 5 | 1 | |||
400/5 | 5 | 5 | 1 | |||
500/5 | 10 | 10 | 5 | 5 | 5 | 1 |
600/5 | 10 | 10 | 5 | 5 | 5 | 1 |
750/5 | 10 | 10 | 10 | 10 | 5 | 1 |
800/5 | 10 | 10 | 10 | 10 | 5 | 1 |
150/1 | 5 | 2.5 | 1 | |||
200/1 | 5 | 5 | 1 | |||
250/1 | 5 | 5 | 1 | |||
300/1 | 5 | 5 | 1 | |||
400/1 | 5 | 5 | 1 | |||
500/1 | 10 | 10 | 5 | 1 | ||
600/1 | 10 | 10 | 5 | 1 | ||
750/1 | 10 | 10 | 5 | 1 | ||
800/1 | 10 | 10 | 5 | 1 |
Type | Size Specification | Overall dimensions | Hole size | |||
W | H | D | d | a | ||
LMK2(BH)-0.66 50I | 35×50 | 83 | 98 | 45 | 36 | 50.5 |
Rated ratio | Rated burden (VA) | Through core winding | ||||
1 | 0.5 | 0.5S | 0.2 | 0.2S | ||
150/5 | 5 | 2.5 | 1 | |||
200/5 | 5 | 5 | 1 | |||
250/5 | 5 | 5 | 1 | |||
300/5 | 5 | 5 | 1 | |||
400/5 | 5 | 5 | 1 | |||
500/5 | 10 | 10 | 5 | 5 | 5 | 1 |
600/5 | 10 | 10 | 5 | 5 | 5 | 1 |
750/5 | 10 | 10 | 10 | 10 | 5 | 1 |
800/5 | 10 | 10 | 10 | 10 | 5 | 1 |
1000/5 | 10 | 10 | 10 | 10 | 5 | 1 |
1200/5 | 10 | 10 | 10 | 10 | 5 | 1 |
1500/5 | 20 | 20 | 20 | 20 | 10 | 1 |
150/1 | 5 | 2.5 | 1 | |||
200/1 | 5 | 5 | 1 | |||
250/1 | 5 | 5 | 1 | |||
300/1 | 5 | 5 | 1 | |||
400/1 | 5 | 5 | 1 | |||
500/1 | 10 | 10 | 5 | 1 | ||
600/1 | 10 | 10 | 5 | 1 | ||
750/1 | 10 | 10 | 10 | 1 | ||
800/1 | 10 | 10 | 10 | 1 | ||
1000/1 | 10 | 10 | 10 | 1 | ||
1200/1 | 10 | 10 | 10 | 1 | ||
1500/1 | 20 | 20 | 20 | 1 |
Type | Size | Overall dimensions | Hole size | |||
W | H | D | d | a | ||
LMK2(BH)-0.66 60I | 45×60 | 99 | 128 | 44 | 45 | 61.5 |
Rated ratio | Rated burden (VA) | Through core winding | ||||
1 | 0.5 | 0.5S | 0.2 | 0.2S | ||
300/5 | 5 | 5 | 1 | |||
400/5 | 5 | 5 | 1 | |||
500/5 | 10 | 10 | 1 | |||
600/5 | 10 | 10 | 1 | |||
750/5 | 10 | 10 | 10 | 10 | 5 | 1 |
800/5 | 10 | 10 | 10 | 10 | 5 | 1 |
1000/5 | 10 | 10 | 10 | 10 | 5 | 1 |
1200/5 | 15 | 15 | 15 | 15 | 5 | 1 |
1500/5 | 15 | 15 | 15 | 15 | 10 | 1 |
2000/5 | 20 | 20 | 20 | 20 | 10 | 1 |
2500/5 | 20 | 20 | 20 | 20 | 10 | 1 |
3000/5 | 25 | 25 | 25 | 25 | 10 | 1 |
300/1 | 5 | 5 | 1 | |||
400/1 | 5 | 5 | 1 | |||
500/1 | 10 | 10 | 1 | |||
600/1 | 10 | 10 | 10 | 1 | ||
750/1 | 10 | 10 | 10 | 1 | ||
800/1 | 10 | 10 | 10 | 1 | ||
1000/1 | 10 | 10 | 10 | 1 | ||
1200/1 | 15 | 15 | 15 | 1 | ||
1500/1 | 15 | 15 | 15 | 1 | ||
2000/1 | 20 | 20 | 20 | 1 | ||
2500/1 | 20 | 20 | 20 | 1 | ||
3000/1 | 25 | 25 | 25 | 1 |
Type | Size Specification | Overall dimensions | Hole size | |||
W | H | D | d | a | ||
LMK2(BH)-0.66 80I | 50×80 | 118 | 138 | 45 | 52 | 80.5 |
Rated ratio | Rated burden (VA) | Through core winding | ||||
1 | 0.5 | 0.5S | 0.2 | 0.2S | ||
600/5 | 10 | 10 | 5 | 10 | 5 | 1 |
750/5 | 10 | 10 | 10 | 10 | 5 | 1 |
800/5 | 10 | 10 | 10 | 10 | 10 | 1 |
1000/5 | 10 | 10 | 10 | 10 | 10 | 1 |
1200/5 | 10 | 10 | 10 | 10 | 10 | 1 |
1500/5 | 15 | 15 | 15 | 15 | 10 | 1 |
2000/5 | 15 | 15 | 15 | 15 | 10 | 1 |
2500/5 | 25 | 25 | 25 | 25 | 10 | 1 |
3000/5 | 25 | 25 | 25 | 25 | 10 | 1 |
600/1 | 10 | 10 | 10 | 1 | ||
750/1 | 10 | 10 | 10 | 1 | ||
800/1 | 10 | 10 | 10 | 1 | ||
1000/1 | 10 | 10 | 10 | 1 | ||
1200/1 | 10 | 10 | 10 | 1 | ||
1500/1 | 15 | 15 | 15 | 1 | ||
2000/1 | 15 | 15 | 15 | 1 | ||
2500/1 | 25 | 25 | 25 | 1 | ||
3000/1 | 25 | 25 | 25 | 1 |
Type | Size Specification | Overall dimensions | Hole size | |||
W | H | D | d | a | ||
LMK2(BH)-0.66 100I | 60×100 | 154 | 145 | 45 | 61 | 100.5 |
Rated ratio | Rated burden (VA) | Through core winding | ||||
1 | 0.5 | 0.5S | 0.2 | 0.2S | ||
1000/5 | 10 | 10 | 10 | 10 | 5 | 1 |
1200/5 | 10 | 10 | 10 | 10 | 5 | 1 |
1500/5 | 15 | 15 | 15 | 15 | 10 | 1 |
2000/5 | 15 | 15 | 15 | 15 | 10 | 1 |
2500/5 | 30 | 30 | 30 | 30 | 30 | 1 |
3000/5 | 30 | 30 | 30 | 30 | 30 | 1 |
4000/5 | 30 | 30 | 30 | 30 | 30 | 1 |
1000/1 | 10 | 10 | 10 | 1 | ||
1200/1 | 10 | 10 | 10 | 1 | ||
1500/1 | 15 | 15 | 15 | 1 | ||
2000/1 | 15 | 15 | 15 | 1 | ||
2500/1 | 30 | 30 | 30 | 1 | ||
3000/1 | 30 | 30 | 30 | 1 | ||
4000/1 | 30 | 30 | 30 | 1 |
Type | Size Specification | Overall dimensions | Hole size | |||
W | H | D | d | a | ||
LMK2(BH)-0.66 120I | 60×120 | 190 | 136 | 46 | 62 | 126 |
Hyliton Power Technology is one of the largest and experienced manufacturers and suppliers of high-tech products in China who can offer you advanced and high quality rectangular current transformers OEM at competitive price. Welcome to order our CE rectangular current transformers made in China.
Download the specifications of BH-0.66、LMK2-0.66I series of current transformers Transformers
Previous: no more
Next: no more
Copyright Beijing Hyliton Power Technology Co.,Ltd. All rights reserved.