Beijing Hyliton Power Technology Co.,Ltd.
Address:6th floor of Tower B, Advanced Material Building, Yongfeng Industrial Base, Haidian Dist., Beijing, 100094 China.
Contact: Ms. Sarah Wang
Tel: +86 189 0119 4516
Mobile phone: +86 10 5871 1928 ext. 1759
Fax: +86 10 5871 1938
E-mail:overseas@hyliton.com
Overview: The TTU301 is installed in the station area of pole mounted transformer, which has th···
Overview:
The TTU301 is installed in the station area of pole mounted transformer, which has the functions of power distribution, energy metering, reactive power compensation, three-phase load unbalance management, and the automatic measurement, acquisition, protection, monitoring, safety protection, etc. of power supply and consumption information for 0.4kV low voltage equipment of distribution transformer.
Features:
l Distribution transformer monitoring: Real-time collection and uploading of voltage, current, temperature and humidity data in the station area
l Automatic meter reading: Data collection of total meter in station area, to obtain the refined operation data of station area, the extendable broadband carrier reads the user’s meter data.
l Equipment monitoring: Automatic monitoring of equipment such as feeder switches and leakage switches in the station area.
l Intelligent reactive power compensation monitoring: Real-time data collection of intelligent reactive power compensation equipment.
l Micro-power wireless maintenance: Due to the complex environment of the installation location of the box, the terminal provides convenient on-site wireless debugging and upgrade.
l Three-phase unbalance management: Perform balance adjustment using commutation device according to the monitoring of three-phase unbalance situation in the station area.
l Fault location and indication: In-situ indication and automatic report by monitoring information such as its own status, external switch faults, etc.
l Safety protection: Information safety protection based on embedded security chip.
Technical Parameters:
Power supply
|
Rated voltage
|
AC220V/380V, 50Hz |
Allowable deviation
|
-30%~+30%
| |
Rated current
|
5A | |
Precise measurement range
| Voltage | 176-264V |
Current | 0-6A | |
Frequency | 45Hz-55Hz | |
Measurement accuracy
| Voltage | ≤±0.5% |
Current | ≤±0.5% | |
Frequency | ≤0.01Hz | |
Active power
| ≤±1% | |
Reactive power
| ≤±1% | |
Power factor
| ≤±1% | |
inspecting power
| ≤±1.0% | |
Electrical measurement
| ≤1.0% | |
Terminal static power consumption
| ≤10 VA | |
Power consumption
| Voltage current Loop power consumption
| ≤0.5VA
|
Backup power
| Super capacitor
| |
Communication channel
| RS485, 4G mobile, micro power wireless, Ethernet, carrier interface, USB |
Download the specifications of TTU301 Smart Distribution Transformer Terminal Unit Transformers
TTU301 Smart Distribution Transformer Terminal.pdf